Public Notice: Building Fire & Life Safety Requirements
Public Notice · Lahore · The Express Tribune,
Notice advertisement published in The Express Tribune on Thursday, 3 September 2026, listed under Lahore.
The original image is temporarily unavailable. Use the source link or the details below. Open the full-size clipping Advertisement details
This public notice lists mandatory fire and life-safety measures for buildings and warns owners of liability for non-compliance. Building owners and managers should ensure these systems, equipment and access provisions are in place, maintained and tested regularly.
| Requirement | Details / Action |
|---|---|
| Safety Manager & Emergency Response Team | Appoint team for regular emergency evacuation drills and daily safety inspections. |
| Encroachment-Free Access | Buildings must be located on a minimum 30-foot unobstructed road. |
| Emergency Staircases | Maximum 100 feet apart; provide signage, floor marking, emergency lights; ventilated and unobstructed. |
| Clear Basement Access | At least two exits on opposite sides; no hazardous material, boiler or kitchen in the basement. |
| Floor Separators in Electrical Ducts | Separate ducts with 4 mm metal sheet and apply fire-resistant sealants around cables. |
| Fire Extinguishers (DCP-6Kg) | Place near exits, maximum 75 ft apart; one extinguisher per 2,000 sq ft of floor area. |
| External Fire Hydrant | Red pillar type at easily accessible points with two 2.5" outlets and instantaneous coupling. |
| Smoke & Flame Detection / IR Cameras / Alarm System | Install in all common areas and corridors with uninterrupted power supply and 24/7 surveillance by trained safety & security staff. |
| Fire Alarm System (Audible & Visual) | Provide manual pull stations or push-button call points near exits. |
| Internal Stand Pipe System (Wet Riser) | Provide on each floor with 2.5" diameter coupling and 1.5" hose with nozzle. |
| Automatic Sprinkler System | Install in all spaces containing combustible material. |
| Fire Dampers in HVAC | Install dampers and insulate ducts with fire-retardant materials. |
| First Aid & Escape Equipment | Provide a first aid box and two fire-escape masks at each floor entrance, security posts, reception or nursing stations. |
| Owner Liability | In case of non-compliance, the owner shall be liable for any loss of life or property. |
Property owners, facility managers and safety officers should audit their buildings against the above checklist and implement or upgrade systems where required. No issuing authority or submission deadline is specified in this notice.
Published in The Express Tribune on Thursday, 3 September 2026. DailyAds.pk indexes newspaper advertisements; the original notice and the issuing organisation remain the source for final terms and eligibility.