Issued by the Emergency Services Department, Government of the Punjab (Rescue 1122). Building owners and managers are required to ensure essential fire and life-safety measures are in place. Non-compliance may render the owner liable for loss of life or property.
Required safety measures and minimum standards:
| Requirement | Details / Minimum Standard |
|---|---|
| Safety Manager & Emergency Response Team | Regular emergency evacuation drills and daily safety inspections. |
| Smoke & Flame Detection / IR Cameras / Alarm System | Installed in common areas and corridors with uninterrupted power supply and 24/7 surveillance by trained safety & security staff. |
| Encroachment-Free Building Access | Located on a minimum 30 ft unobstructed road. |
| Fire Alarm System | Audible and visual appliances; manual pull stations or push-button call points near exits. |
| Emergency Staircases | Maximum 100 ft apart with signage, floor marking and emergency lights; ventilated and unobstructed. |
| Internal Stand Pipe System (Wet Riser) | On each floor with 2.5 inch diameter coupling and 1.5 inch hose with nozzle. |
| Clear Access to Basements | At least two exits on opposite sides. No hazardous material, boiler or kitchen in basement. |
| Automatic Sprinkler System | Required in all spaces having any combustible material. |
| Floor Separators in Electrical Ducts | Separated by 4 mm metal sheet and fire-resistant sealants around cables. |
| Fire Dampers in HVAC | Fire dampers and insulation of ducts with fire-retardant materials. |
| Fire Extinguishers (DCP-6Kg) | Near exits, maximum 75 ft apart; one per 2,000 sq ft floor area. |
| First Aid Box & Fire Escape Masks | At each floor entrance, security posts, reception or nursing stations; at least 2 fire escape masks. |
| External Fire Hydrant | Red pillar type at safe, easily accessible points with 2 outlets of 2.5" dia and instantaneous coupling. |
| Compliance Warning | In case of non-compliance, the owner shall be liable for any loss of life or property. |
This notice is a general mandatory checklist for building fire and life-safety measures as published by the Emergency Services Department, Government of the Punjab (Rescue 1122). Follow local enforcement instructions for inspections and enforcement actions.
Published in Nawa-i-Waqt on Thursday, 3 September 2026. DailyAds.pk indexes newspaper advertisements; the original notice and the issuing organisation remain the source for final terms and eligibility.
Questions about this notice
- What is the last date for this notice?
- This advertisement prints no last date. Read the clipping and confirm with Public Safety Notice.
- Which newspaper published this notice?
- Nawa-i-Waqt, in the edition of Thursday, 3 September 2026.
- Which city is this notice for?
- Islamabad — the location listed for this advertisement.
- How do I respond to this notice?
- Follow the instructions printed in the clipping; the advertiser’s own page is linked from this one. Applications are not submitted through this page.