Issued by the Emergency Services Department, Government of the Punjab (Rescue 1122). Building owners and managers are required to ensure essential fire and life-safety measures are in place. Non-compliance may render the owner liable for loss of life or property.

Required safety measures and minimum standards:

Requirement Details / Minimum Standard
Safety Manager & Emergency Response Team Regular emergency evacuation drills and daily safety inspections.
Smoke & Flame Detection / IR Cameras / Alarm System Installed in common areas and corridors with uninterrupted power supply and 24/7 surveillance by trained safety & security staff.
Encroachment-Free Building Access Located on a minimum 30 ft unobstructed road.
Fire Alarm System Audible and visual appliances; manual pull stations or push-button call points near exits.
Emergency Staircases Maximum 100 ft apart with signage, floor marking and emergency lights; ventilated and unobstructed.
Internal Stand Pipe System (Wet Riser) On each floor with 2.5 inch diameter coupling and 1.5 inch hose with nozzle.
Clear Access to Basements At least two exits on opposite sides. No hazardous material, boiler or kitchen in basement.
Automatic Sprinkler System Required in all spaces having any combustible material.
Floor Separators in Electrical Ducts Separated by 4 mm metal sheet and fire-resistant sealants around cables.
Fire Dampers in HVAC Fire dampers and insulation of ducts with fire-retardant materials.
Fire Extinguishers (DCP-6Kg) Near exits, maximum 75 ft apart; one per 2,000 sq ft floor area.
First Aid Box & Fire Escape Masks At each floor entrance, security posts, reception or nursing stations; at least 2 fire escape masks.
External Fire Hydrant Red pillar type at safe, easily accessible points with 2 outlets of 2.5" dia and instantaneous coupling.
Compliance Warning In case of non-compliance, the owner shall be liable for any loss of life or property.

This notice is a general mandatory checklist for building fire and life-safety measures as published by the Emergency Services Department, Government of the Punjab (Rescue 1122). Follow local enforcement instructions for inspections and enforcement actions.

Published in Nawa-i-Waqt on Thursday, 3 September 2026. DailyAds.pk indexes newspaper advertisements; the original notice and the issuing organisation remain the source for final terms and eligibility.

Questions about this notice

What is the last date for this notice?
This advertisement prints no last date. Read the clipping and confirm with Public Safety Notice.
Which newspaper published this notice?
Nawa-i-Waqt, in the edition of Thursday, 3 September 2026.
Which city is this notice for?
Islamabad — the location listed for this advertisement.
How do I respond to this notice?
Follow the instructions printed in the clipping; the advertiser’s own page is linked from this one. Applications are not submitted through this page.
Nawa-i-Waqt · 03 Sep 2026
Fit