Public Safety Checklist for Buildings — Emergency Services Department, Government of the Punjab
Public Safety Checklist for Buildings · Lahore · Jang,
Notice advertisement published in Jang on Thursday, 3 September 2026, listed under Lahore. Issued by Public Safety Checklist for Buildings.
The original image is temporarily unavailable. Use the source link or the details below. Open the full-size clipping Advertisement details
Issued by the Emergency Services Department, Government of the Punjab (Rescue 1122). This public notice outlines mandatory fire-safety and emergency preparedness requirements for buildings to protect life and property. Non-compliance may render the owner liable for loss of life or property.
| Requirement | Details / Minimum Standard |
|---|---|
| Safety Management | Designated Safety Manager & Emergency Response Team; regular evacuation drills and daily safety inspections. |
| Encroachment-free Access | Building must be located on a minimum 30 ft unobstructed road. |
| Emergency Staircases | Maximum 100 ft apart; must have signage, floor markings and emergency lights; ventilated and unobstructed. |
| Basement Access | At least two exits on opposite sides; no hazardous material, boilers or kitchens allowed in basement. |
| Floor Separators in Electrical Ducts | Separated by 4 mm metal sheet and sealed with fire-resistant sealants around cables. |
| Fire Extinguishers | DCP 6 kg units near exits; maximum 75 ft spacing; one per 2,000 sq ft floor area. |
| External Fire Hydrant | Red pillar type at safe, easily accessible points with two outlets of 2.5" dia and instantaneous coupling. |
| Smoke & Flame Detection / CCTV | IR cameras and alarm system in common areas & corridors with uninterrupted power and 24/7 surveillance by trained staff. |
| Fire Alarm System | Audible & visual appliances; manual pull stations or push-button call points near exits. |
| Internal Stand Pipe (Wet Riser) | On each floor with 2.5" diameter coupling and 1.5" hose with nozzle. |
| Automatic Sprinkler System | Required in spaces having any combustible material. |
| Fire Dampers in HVAC | Fire dampers and insulation of ducts with fire-retardant materials. |
| First Aid & Escape Equipment | First aid box and two fire escape masks at each floor entrance, security posts and reception or nursing stations. |
Owners and managers should implement these measures immediately to ensure compliance and protect occupants. For emergency response and fire safety services see Rescue 1122.
Published in Jang on Thursday, 3 September 2026. DailyAds.pk indexes newspaper advertisements; the original notice and the issuing organisation remain the source for final terms and eligibility.
Questions about this notice
- What is the last date for this notice?
- This advertisement prints no last date. Read the clipping and confirm with Public Safety Checklist for Buildings.
- Which newspaper published this notice?
- Jang, in the edition of Thursday, 3 September 2026.
- Which city is this notice for?
- Lahore — the location listed for this advertisement.
- How do I respond to this notice?
- Follow the instructions printed in the clipping; the advertiser’s own page is linked from this one. Applications are not submitted through this page.